The operation and interval time of CEN01 are controlled by PLC.
CEN01 has a pressure gauge that enables the user to check the operating pressure easily.
CEN01 has a 1kgf/cm2 NC contact socket pressure switch that detects the operating pressure automatically and send signals when the pressure is below the preset value.
CEN01 has a NC contact float switch that detects the oil level automatically and sends signals when the oil level is low.
CEN01 has a spark quencher that prevents the spark of switch contacts and the interference of surge voltage with the PLC and prolongs the service life.
CEN01 has a feed-oil button, which can be used as manual oil feeding for less than 3 minutes to avoid overloading the motor.
CEN01 has a thermal control that shuts down the motor for about 5 minutes when the motor is overheated.