The time adjusters are inside the control box of CESP. There are eight kinds of operation time and interval time for selection.
There are operation (ACT) and interval (INT) indicators on the control box.
There are two operation modes after the power of CESP is on. The standard mode is turn-on-interval.
● Turn-on-feeding: Operation time starts first after the power is on.
● Turn-on-interval: Interval time starts first after the power is on.
Turn-on-interval model has a memory function. If the power is suddenly off during the interval time, CESP will continue to operate from the remaining interval time after restarting, which can effectively avoid over-lubrication.
CESP has a NC contact float switch that detects the oil level automatically and sends signals when the oil level is low.
CESP has a buzzer that sends an alarm sound when the oil level is low.
CESP has a feed-oil button (F button), which can be used as manual oil feeding for less than 3 minutes to avoid overloading the motor.
CESP has a thermal control that shuts down the motor for about 5 minutes when the motor is overheated.