CEN04 has a timer that controls its operation and interval time. The control box has a built-in buzzer that sends an alarm sound when the oil level is low. The control box also has four indicators, operation (ACT), alarm (ALM), immediate lubrication (RUN), and interval (INT).
CEN04 has to work with volume distributors to deliver the metered quantity of oil to the lubrication points.
CEN04 can memorize the set value of operation time and interval time.
There are two operation modes after the power of CEN04 is on. The standard mode is turn on feeding.
● Turn-on-feeding: Operation time starts first after the power is on.
● Turn-on-interval: Interval time starts first after the power is on.
Turn-on-interval model has a memory function. If the power is suddenly off during the interval time, CEN04 will continue to operate from the remaining interval time after restarting, which can effectively avoid over-lubrication.
CEN04 has a pressure gauge that enables the user to check the operating pressure easily.
CEN04 has an 8kgf/cm2 NC contact socket pressure switch that detects the operating pressure automatically.
CEN04 has a NC contact float switch that detects the oil level automatically and sends signals when the oil level is low.
CEN04 has a feed-oil button (F button), which can be used as manual oil feeding for less than 3 minutes to avoid overloading the motor.
CEN04 has a thermal control that shuts down the motor for about 5 minutes when the motor is overheated.