The operation and interval time adjusters are on the control box of CEWB. There are operation (ACT) and interval (INT) indicators on the control box.
There are two operation modes after the power of CEWB is on. The standard mode is turn on interval.
● Turn-on-feeding: Operation time starts first after the power is on.
● Turn-on-interval: Interval time starts first after the power is on.
Turn-on-interval model has a memory function. If the power is suddenly off during the interval time, CEWB will continue to operate from the remaining interval time after restarting, which can effectively avoid over-lubrication.
CEWB has to work with volume distributors to deliver the metered quantity of oil to the lubrication points.
CEWB has a pressure gauge that enables the user to check the operating pressure easily.
CEWB has a NC contact float switch that detects the oil level automatically and sends signals when the oil level is low.
CEWB has a buzzer that sends an alarm sound when the oil level is low.
CEWB has a feed-oil button (F button), which can be used as manual oil feeding for less than 3 minutes to avoid overloading the motor.
CEWB has a thermal control that shuts down the motor for about 5 minutes when the motor is overheated.